This document is a technical datasheet for the Teledyne e2v CX2610, a deuterium-filled, double-gap ceramic thyratron designed for high-voltage pulse switching and pulse modulator service. It details the device's electrical, mechanical, and environmental specifications, absolute maximum and minimum ratings, operating characteristics, recommended triggering and cooling configurations, schematic connections, safety guidelines, and outline dimensions.
Analysis Confidence: High
ST_CODE: CX2610
System Metadata
Source ID
DOC-CX2610
Process Date
Public archive record
Integrity Hash
SHA256-CX2610...
Indexer Status
COMPLETE
Initializing_Secure_Viewer...
Full Transcript
Transcript
Page 1 of 6
Page 1 - General Information and Data
TELEDYNE e2v
CX2610
Two-Gap, Deuterium Filled, Ceramic Thyratron
The data to be read in conjunction with the Hydrogen Thyratron Preamble.
ABRIDGED DATA
Deuterium filled, double-gap, high voltage thyratron with ceramic envelope, featuring high peak current, high rate of rise of current, low jitter and drift. The tube can switch high peak currents with short pulse durations at very high rates of rise of current, and is also suitable for general pulse modulator service at longer pulse durations.
A reservoir operated from a separate heater supply is incorporated. The reservoir heater voltage can be adjusted to a value consistent with anode voltage hold-off in order to achieve the fastest rate of rise of current possible from the tube in the circuit.
Peak forward anode voltage: 55 kV max
Peak forward anode current: 10 kA max
Average anode current: 2.0 A max
Rate of rise of anode current: 100 kA/µs
GENERAL DATA
Electrical
Cathode (connected internally to one end of heater): Oxide coated
Cathode heater voltage: 6.3 + 0.5 V
Cathode heater current: 24.0 A
Reservoir heater voltage (nominal, see note 1): 5.0 V
Reservoir heater current (at 5.0 V): 7.0 A
Tube heating time (minimum): 10 min
Mechanical
Seated height: 182.28 mm (7.176 inches) nom
Clearance required below mounting flange: 50.8 mm (2.000 inches) min
Overall diameter (mounting flange): 111.1 mm (4.375 inches) nom
Net weight: 2.2 kg (4.75 pounds) approx.
Mounting position (see note 2): Any
Tube connections: See outline
Whilst Teledyne e2v has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. Teledyne e2v accepts no liability beyond that set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of tubes or other devices in accordance with information contained herein.
Teledyne UK Limited, Waterhouse Lane, Chelmsford, Essex CM1 2QU United Kingdom Teledyne UK Ltd. is a Teledyne Technologies company.
Telephone: +44 (0)1245 493493 Facsimile: +44 (0)1245 492492
Contact Teledyne e2v by e-mail: [email protected] or visit www.teledyne-e2v.com for global sales and operations centres.
© Teledyne UK Limited 2023 A1A-CX2610 Version 5, April 2023 Approved for public release: Teledyne e2v APPROVED (CM 5002586)
Frequently Asked Questions
What is this document? ▾
This document is a technical datasheet for the Teledyne e2v CX2610, a deuterium-filled, double-gap ceramic thyratron designed for high-voltage pulse switching and pulse modulator service. It details the device's electrical, mechanical, and environmental specifications, absolute maximum and minimum r...