Primary Intelligence Asset
Portable Diagnostic Package for Thomson scattering and Optical Emission Spectroscopy on Princeton Field-reversed Configuration 2 (PFRC 2)
Declassified Public record OCR verified
INTEL
Executive Summary
This paper describes the deployment and implementation of a Portable Diagnostic Package (PDP) combining Thomson Scattering (TS) and Optical Emission Spectroscopy (OES) on the Princeton Field-reversed Configuration 2 (PFRC-2) device. Due to high laser stray light and low plasma electron densities, stray light mitigation techniques including a narrow-band Volume Bragg Grating (VBG) notch filter were implemented, improving TS light discrimination sensitivity by 65 times and lowering the electron density discrimination threshold to 1 ± 0.5 × 10^18 m^-3.
Analysis Confidence: High
ST_CODE: 101849
System Metadata
Source ID
DOC-DOI_10.1
Process Date
Public archive record
Integrity Hash
SHA256-DOI101063501...
Indexer Status
COMPLETE
Initializing_Secure_Viewer...
Full Transcript
Transcript
Page 1 of 6
Title and Abstract
Portable Diagnostic Package for Thomson scattering and Optical Emission Spectroscopy on Princeton Field-reversed Configuration 2 (PFRC 2)
N. Kafle, D. Elliott, B. Berlinger, Z. He, S. Cohen, Z. Zhang, and T. M. Biewer
1) Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA
2) Princeton Plasma Physics Laboratory, Princeton, NJ 08543, USA
3) University of Tennessee-Knoxville, Knoxville, TN 37996, USA
(*Author to whom correspondence should be addressed: [email protected])
(Dated: 26 September 2022)
An Advanced Research Projects Agency-Energy (ARPA-E) funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (< 2 × 10^19 m^-3) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be > 1 × 10^20 m^-3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch-filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from the Rayleigh and Rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. The Raman scattering calibration with the notch-filter has improved the PDP electron density threshold to 1 ± 0.5 × 10^18 m^-3.
Frequently Asked Questions
What is this document? ▾
This paper describes the deployment and implementation of a Portable Diagnostic Package (PDP) combining Thomson Scattering (TS) and Optical Emission Spectroscopy (OES) on the Princeton Field-reversed Configuration 2 (PFRC-2) device. Due to high laser stray light and low plasma electron densities, st...